Related Experiment Video
Updated: Dec 31, 2025

Experimental Autoimmune Uveitis: An Intraocular Inflammatory Mouse Model
Published on: January 12, 2022
HAE-AS: A Specific Disease Activity Scale for Hereditary Angioedema With C1-Inhibitor Deficiency
M J Forjaz1, A Ayala1, M Caminoa2
1National School of Public Health, Institute of Health Carlos III and REDISSEC, Madrid, Spain.
Background And Objective:
The activity of hereditary angioedema due to C1-inhibitor deficiency (C1-INH-HAE) varies between patients and within individual patients. Objective: This study aims to develop a disease activity scale for C1-INH-HAE (HAE-AS) with sound measurement properties.
Methods:
Eleven countries participated in a prospective multicenter cohort study. A clinical questionnaire was self-completed by 290 adult patients with C1-INH-HAE. Patients also completed 2 quality of life scales, the SF-36v2 and the HAE-QoL. Rasch analysis and classic psychometric methods were used to preselect a series of clinical items: number of attacks by location and number of treated attacks, emergency room visits, psychological/psychiatric treatment, missed school/workdays in the previous 6 months; general health; and impairment in everyday work/activities due to pain.
Results:
The mean (SD) age was 41.5 (14.7; range, 18-84) years, and 69% were females. The final 12-item Rasch model showed that the HAE-AS had satisfactory reliability (person separation index, 0.748), local item independence, unidimensionality, and no item bias by age or sex. The HAE-AS provided scores in a linear measure, with a mean of 10.66 (3.92; range, 0-30). Further analysis with classic psychometric methods indicated that the HAE-AS linear measure presented moderate-to-high convergent validity with quality of life scales (SF-36v2: physical component, r=-0.33; mental component, 0.555; HAE-QoL, -0.61), and good discriminative validity by age, sex, and disease severity (P<.05).
Conclusions:
The HAE-AS is a short, valid, reliable, and psychometrically sound measure of the activity of C1-INH-HAE that could prove useful for research studies.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...