Dosimetric analysis of hands exposure during handling of strong permanent magnets
Mauro David1,2, Gernot Schmid1,2
1Seibersdorf Laboratories, Dept. EMC & Optics, A-2444 Seibersdorf, Austria.
Abstract:
Workers in a production line for synchronous motors occasionally reported tingling sensations or a feeling of numbness in their hands when handling strong permanent magnets. As the magnetic flux density (B) and its gradients along and close to the surface of the permanent magnets were expected to be comparably high and the movements of the workers' hands may therefore cause relevant induction inside the tissue, a detailed dosimetric analysis of the in situ electric field inside the hands (Ei) of the workers was carried out. The time derivate of the magnetic flux density (dB/dt) occurring along the hands was determined based on time domain measurements using a specially developed 'measurement glove' containing 12 Hall sensors. Based on these measurement results temporal peak electric field strength (Ei) induced inside a newly developed high resolution anatomical hand models were numerically computed, using the scalar potential finite difference (SPFD) method. The highest measured dB/dt along the palmar side of the hand was 51.2 T s-1. The corresponding worst case temporal peak value of the maximum of the Ei averaged over 2 × 2 × 2 mm3 in soft tissue was 2.0 V m-1, which is a factor of 1.8 higher than the applicable exposure limit value, but still below the range of 3.8-6.2 V m-1 which is presently assumed the range of lowest stimulation threshold for peripheral nerves. Our analysis did therefore not provide an indication that the perception reported by the workers are due to tissue stimulation in the sense of provoking action potentials.
More Related Videos
09:35Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019
Related Concept Videos
Potential Due to a Magnetized Object
The vector...
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Diamagnetism
Diamagnetism was discovered by Anton Brugmans in 1778 when he observed that bismuth gets repelled by magnetic fields, thus theorizing that diamagnets get repelled by magnets....
Paramagnetism
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
Ferromagnetism