Related Experiment Video
Updated: Dec 30, 2025

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Comparison of Time-of-Flight and Phase-Shift TLS Intensity Data for the Diagnostics Measurements of Buildings
1Faculty of Civil Engineering Environmental and Geodetic Sciences, Koszalin University of Technology, Śniadeckich 2, 75-453 Koszalin, Poland.
Abstract:
In recent years, the terrestrial laser scanning system (TLS) has become one of the most popular remote and nondestructive testing (NDT) methods for diagnostic measurements of buildings and structures as well as for the assessment of architectural heritage. Apart from 3D coordinates, the power of a laser beam backscattered from the scanned object can be captured by TLS. The radiometric information of the point cloud, called "intensity", can provide information about changes in the physio-chemical properties of the scanned surface. This intensity can be effectively used to detect defects in the surfaces of walls, such as cracks and cavities, moisture, biodeterioration (mosses and lichens) or weathered parts of the wall. Manufacturers of TLS mainly use two different principles for distance measurement, time-of-flight (TOF) and phase-shift (PS). The power of energy in both types of rangefinders might be absorbed or reflected in a slightly different way and provide more or less detailed radiometric point cloud information. The main aim of this investigation is to compare TOF and PS scanners in the context of using TLS intensity data for the diagnostics of buildings and other structures. The potential of TLS intensity data for detecting defects in building walls has been tested on multiple samples by two TOF (Riegl VZ400i, Leica ScanStation C10) and two PS (Z + F 5016 IMAGER, Faro Focus3D) scanners.
Related Concept Videos
Electronic Distance Measuring Instruments
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

