Areen Allataifeh1, Mahmoud Al Ahmad2
1Department of Electrical Engineering, College of Engineering, United Arab Emirates University, Al Ain, 15551, UAE.
Abstract:
The monitoring of vital signs plays a key role in the diagnosis of several diseases. Piezoelectric sensors have been utilized to collect a corresponding representative signal from the chest surface. The subject typically needs to hold his or her breath to eliminate the respiration effect. This work further contributes to the extraction of the corresponding representative vital signs directly from the measured respiration signal. The contraction and expansion of the heart muscles, as well as the respiration activities, will induce a mechanical vibration across the chest wall. The induced vibration is then captured by the piezoelectric sensor placed at the chest surface, which produces an electrical output voltage signal conformally mapped with the respiration-cardiac activities. During breathing, the measured voltage signal is composed of the cardiac cycle activities modulated along with the respiratory cycle activity. A representative model that incorporates the cardiac and respiratory activities is developed and adopted. The piezoelectric and the convolution theories along with Fourier transformation are applied to extract the corresponding cardiac activity signal from the respiration signal. All the results were validated step by step by a conventional apparatus, with good agreement observed.
More Related Videos
07:02Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
10:07Simultaneous Recordings of Cortical Local Field Potentials, Electrocardiogram, Electromyogram, and Breathing Rhythm from a Freely Moving Rat
Published on: April 2, 2018
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...