    Abstract:

    This paper presents the development and implementation at a prototype level of a wireless, low-cost system for the measurement of the electrical bio-impedance of the chest with two channels using the AD5933 in a bipolar electrode configuration to measure lung volume variation. 15 volunteers were measured with the prototype, and the acquired signal presents the phases of the respiratory cycle, useful for the breathing rate calculation and for possible screening applications.

    More Related Videos

    Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
    07:17

    Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis

    Published on: August 17, 2022

    3.2K
    Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
    07:44

    Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass

    Published on: July 14, 2023

    1.6K

    Related Experiment Videos

    Last Updated: Dec 30, 2025

    Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
    05:56

    Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit

    Published on: September 6, 2024

    5.8K
    Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
    07:17

    Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis

    Published on: August 17, 2022

    3.2K
    Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
    07:44

    Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass

    Published on: July 14, 2023

    1.6K

    Related Concept Videos

    Lung Capacity01:47

    Lung Capacity

    55.9K
    The air in the lungs is measured in volumes and capacities. Lung volume measures reflect the amount of air taken in, released, or left over after a lung function, like a single inhalation. Lung capacity measures are sums of two or more lung volume measures.
    55.9K
    Pulmonary Function Tests01:25

    Pulmonary Function Tests

    666
    Pulmonary Function Tests (PFTs)
    Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
    PFTs involve using a spirometer, a...
    666

    Articles linked to this work by shared authors, journal, and citation graph.

    Biophysical and functional evaluation of concentric electrodes for localised non-invasive FES.

    Biomedical physics & engineering express·2026

    A Multicenter Standardized Gait Database from the ORITEL Network for Cerebral Palsy Gait Analysis.

    IEEE journal of biomedical and health informatics·2026

    Modular and programmable breathing phantom station for accelerated degradation testing of industrial respirator filters.

    HardwareX·2026

    Surface Electromyography Reveals Subject-Specific Alterations in Lumbar Flexion-Relaxation Following Prolonged Cycling in Pain-Free Road Cyclists.

    Sensors (Basel, Switzerland)·2026

    Neural correlates in the time course of inferences: costs and benefits for less-skilled readers at the university level.

    Frontiers in psychology·2026

    Step-Length Estimation in Asymmetric Gait Using a Single Lower-Back IMU Data and a Biomechanical Model Inspired by a Double Inverted Pendulum.

    Bioengineering (Basel, Switzerland)·2026

    Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Impact of brain anisotropy on transcranial temporal interference stimulation: numerical analysis toward reliable montage optimization.

    Biomedical engineering letters·2026

    Erratum: Safety and Efficacy of a Novel Direct Bladder Wall Stimulation Device in Canines: Erratum.

    JU open plus·2026

    Negative BOLD response to interictal discharges in epilepsy using intracranial EEG-fMRI.

    Neuroimage. Reports·2026

    ICA-S3M: switching state-space model guided automatic EEG artifact removal from independent components.

    Frontiers in neuroscience·2026

    Evaluation of 7 Tesla pTx Body Coils Regarding Transmit and Receive Performance.

    Magnetic resonance in medicine·2026

    Breaking voltage-controlled magnetic anisotropy-magnetoresistance trade-off for ultralow-energy switching in magnetic tunnel junctions.

    Science advances·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us