Related Experiment Video
Updated: Dec 30, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Multi-source signal processing in phonocardiography: comparison among signal selection and signal enhancement
Abstract:
Phonocardiography (PCG) is a promising tool for the diagnosis and follow-up of cardiovascular diseases. To date it is available only in clinical settings, because it relies on an experienced examiner for the positioning of the electronic stethoscope. Making it possible for an unexperienced user to obtain high quality PCG signals would allow for developing instruments suitable for homecare purposes. In this work, we test the usage of three standardly positioned microphone probes. The aim is to compare two different approaches for enhancing the PCG signal quality, namely a) selecting the single source with the highest Signal-to-Noise Ratio (SNR) and b) combining the three sources through array signal processing techniques. Both approaches were tested on a sample population counting 24 healthy subjects. We found that the two approaches above give statistically different results (two-tailed paired t-test, p = 0.037) in terms of SNR of the enhanced signal. Specifically, selecting the single source with highest SNR gives, on average, the best results. Moreover, this approach is also associated with the lowest computational cost. Finally, for every subject of our sample population, we obtained SNR values higher than 12.5 dB on the enhanced signal, which we consider as sufficient for the application of heart sound segmentation and classification algorithms. We believe that this methodology allows for obtaining PCG signals of sufficient quality for the analysis of heart sounds, thus opening to the applicability of PCG in a homecare context.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Upsampling
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...