A Wireless Wearable Sensor Patch for the Real-Time Estimation of Continuous Beat-to-Beat Blood Pressure
Abstract:
This paper proposes a wireless wearable sensor system for the continuous beat-to-beat blood pressure (BP) monitoring. The real-time BP can be estimated utilising a 2-parameter regression model based on the pulse arrival time (PAT) and heart rate (HR). The PAT is defined as the time interval between the electrocardiogram (ECG) R-peak and the corresponding maximum inclination point of photoplethysmography (PPG) signal. A wireless wearable sensor patch designed to be attached to the subject's chest is used for the measurement of ECG and PPG signals. The sensor data are transmitted through a Bluetooth low energy (BLE) module to a computer for the real-time online estimation of BP. To verify the feasibility and performance of the proposed system, a 5-day period experiment is conducted on two healthy male subjects for the training and validation of the BP estimation model. On each day, there are two 15 minutes offline sessions for data collection from the sensor patch, which are compared with the reference BP to calibrate the estimation model parameters. After that, a 10 minutes online session is carried out to validate the regression model against the reference BP device. Eventually, the 5-day period data are combined together for an overall BP estimation model, which has good correlation (r=0.82) with the reference BP measurements. The experimental results show the proposed sensor patch with the BP estimation model is capable of the online real-time BP monitoring after an initial calibration procedure.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: