Related Experiment Video
Updated: Jun 4, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
A Wearable Device with Triboelectric Nanogenerator Sensing for Respiration and Spirometry Monitoring
Hongqiang Xu1, Weiqiao Han1, Mehmet Rasit Yuce1
1Department of Electrical and Computer Systems Engineering, Monash University, Wellington Rd, Clayton, VIC 3800, Australia.
Abstract:
Wearable devices have been developed for the continuous and long-term monitoring of respiration. Although current wearable devices are able to measure the respiration rate, extracting breathing volume has been challenging. In this paper, we propose a wearable respiration monitoring sensor based on triboelectric nanogenerator (TENG) technology. The proposed device successfully measures both respiration rate and volume in real-time. The device is tested with seven participants for respiration and spirometry studies. The results show that the proposed TENG sensor is able to capture the respiration waveform with high accuracy. All breathing patterns mentioned in this study give a mean absolute error (MAE) within 0.2 breaths per minute and a mean percentage absolute (MPAE) error within 2%. The results of the spirometry study show that the TENG sensor can measure the airflow and volume during exhalation. The flow time graph gives an average correlation of 0.88 compared with that of the reference spirometer. The reconstructed volume time plot from the TENG sensor results in an MAE of 2.43% for the ratio of the forced expiratory volume in 1 s to the forced vital capacity (FEV1/FVC). The proposed device provides a low-cost solution for real-time and wearable monitoring for respiration parameter measurement.
More Related Videos
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
09:42Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
Published on: January 24, 2025
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...