Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Correlation Between Doppler Derived Carotid Artery Corrected Flow Time and Pressure Transducer Derived Radial Artery
Souvik Maitra1, Sulagna Bhattacharjee2, Dalim K Baidya1
1Department of Anaesthesiology, Pain Medicine & Critical Care, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Purpose:
Carotid artery corrected flow time (cFT) derived from Doppler USG is a known predictor of volume responsiveness. However, it can't be obtained continuously, and is operator dependent. In this prospective study, correlation between Doppler derived carotid artery cFT and pressure transducer derived radial artery cFT was evaluated in adult patients undergoing surgery under general anaesthesia.
Methods:
Doppler derived carotid artery cFT were obtained from n = 51 adult patients at n = 125 time points. Simultaneously, pressure transducer waveforms were saved at the time of measurement of carotid artery cFT. Later, images were analyzed by an image processing computer software; both pulse pressure variation and cFT were estimated from pressure transducer waveform.
Results:
Radial artery flow times measured by two independent observers, were significantly correlated (r2 = 0.99, p < 0.00001). Bland-Altman analysis found limits of agreement - 8.3 to 6.3 ms [mean difference (95% CI) - 0.98 (- 1.63, - 0.32)]. Doppler derived carotid artery cFT & pressure transducer derived radial artery cFT were also significantly correlated [r2 = 0.78, p < 0.0001]. However, radial artery cFT was significantly higher than carotid artery cFT [p < 0.0001, paired sample t test]. Radial artery cFT > 404.4 ms had an sensitivity and specificity of 87.34% and 85% respectively with a grey zone was between 393.7 and 417 ms to predict PPV ≥ 12%.
Conclusion:
Pressure transducer derived radial artery cFT correlated with Doppler derived carotid artery cFT and may be a reasonable predictor of volume responsiveness. Further studies are required to confirm its role in various clinical scenario for prediction of volume responsiveness.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation