Related Experiment Video
Updated: Dec 30, 2025

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Hollow-fibre liquid-phase microextraction and gas chromatography-mass spectrometric determination of amphetamines in
Henrique Silva Bombana1, Marcelo Filonzi Dos Santos1, Daniel Romero Muñoz1
1Faculty of Medicine, University of Sao Paulo, Av. Dr. Arnaldo, 455 Cerqueira Cesar, Sao Paulo 01246-903, Brazil.
Abstract:
Here, we present a fully validated method using a hollow-fibre liquid-phase microextraction technique for the determination by gas chromatography-mass spectrometry (GC-MS) of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxyethylamphetamine (MDEA) in whole blood. The validation parameters presented successful values within those recommended by the Scientific Working Group for Forensic Toxicology (SWGTox) in the Standard Practices for Method Validation in Forensic Toxicology. The limits of detection ranged from 1 to 3 ng/mL, and the limits of quantification ranged from 2 to 5 ng/mL. The determination coefficients (r2) ranged from 0.990 to 0.997, and the method presented good intraday and interday accuracy (from 90.4% to 97.2%) and satisfactory recovery (from 68% to 110%). No carryover was observed. The heteroscedasticity was tested, and only AMP presented homoscedasticity. Weighting factors were applied to correct the linearity of MET (1/x2), MDA (1/x), FEN (1/x1/2), MDMA (1/x2) and MDEA (1/y). Dilution integrity was tested at ratios of 1:2, 1:5 and 1:10, and all maintained intraday precision (from 94.9% to 99.3%) and interday precision (from 89.4% to 94.9%). The validated method was applied to six real whole blood samples from individuals suspected of consuming ecstasy, and MDMA, MDA and amphetamine were successfully identified and quantified.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Elution Process