Related Experiment Video
Updated: Dec 30, 2025

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Stroke Outcome Prediction by Blood Pressure Variability, Heart Rate Variability, and Baroreflex Sensitivity
Shujin Tang1, Li Xiong2,3, Yuhua Fan1
1From the Department of Neurology, The First Affiliated Hospital, Sun Yat-sen University, and Guangdong Provincial Key Laboratory of Diagnosis and Treatment of Major Neurological Diseases, National Key Clinical Department and Key Discipline of Neurology, Guangzhou, China (S.T., Y.F.).
Abstract:
Background and Purpose- Poststroke autonomic dysfunction portended an unfavorable prognosis. We investigated whether blood pressure variability (BPV), heart rate variability, and baroreflex sensitivity might predict stroke functional outcome. Methods- We calculated BPV, heart rate variability, baroreflex slope, and baroreflex effectiveness index from a 5-minute beat-to-beat blood pressure and heart rate monitoring within 7 days from the stroke onset. We compared the parameters between patients with a good outcome (modified Rankin Scale score, 0-2) and those with a poor outcome. Results- Among 142 patients (mean age, 63.9±10.2 years; 88.0% men), functional outcome was good in 112 (78.9%) and poor in 30 (21.1%). There were significant differences in admission National Institutes of Health Stroke Scale, prior stroke, high-frequency systolic BPV, low/high-frequency ratio of BPV, baroreflex sensitivity-up, and baroreflex sensitivity-total between the 2 groups (all P<0.05). In multivariate analysis, National Institutes of Health Stroke Scale (OR, 1.672 [95% CI, 1.316-2.125]; P<0.001), low/high-frequency ratio of systolic BPV (OR, 0.493 [95% CI, 0.250-0.973]; P=0.041), and baroreflex effectiveness index-down (OR, 0.958 [95% CI, 0.924-0.992]; P=0.017) independently predicted a poor functional outcome. Conclusions- A decreased low/high-frequency ratio of systolic BPV and impaired baroreflex sensitivity predicted an unfavorable stroke outcome, in addition to the established prognostic factor such as the National Institutes of Health Stroke Scale.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

