Related Experiment Video
Updated: Dec 30, 2025

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
How Hot Are Your Ions in Differential Mobility Spectrometry?
Christian Ieritano1, Joshua Featherstone1, Alexander Haack2
1Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
Abstract:
Ions can experience significant field-induced heating in a differential mobility cell. To investigate this phenomenon, the fragmentation of several para-substituted benzylpyridinium "thermometer" ions (R = OMe, Me, F, Cl, H, CN) was monitored in a commercial differential mobility spectrometer (DMS). The internal energy of each benzylpyridinium derivative was characterized by monitoring the degree of fragmentation to obtain an effective temperature, Teff, which corresponds to a temperature consistent with treating the observed fragmentation ratio using a unimolecular dissociation rate weighted by a Boltzmann distribution at a temperature T. It was found that ions are sufficiently thermalized after initial activation from the ESI process to the temperature of the bath gas, Tbath. Once a critical field strength was surpassed, significant fragmentation of the benzylpyridinium ions was detected. At the maximum bath gas temperature (450 K) and separation voltage (SV; 4400 V) for our instrument, Teff for the benzylpyridinium derivatives ranged from 664 ± 9 K (p-OMe) to 759 ± 17 K (p-H). The extent of activation at a given SV depends on the ion's mass, degrees of freedom, (NDoF), and collision frequency as represented by the ion's collision cross section. Plots of Teff vs the product of ion mass and NDoF and the inverse of collision cross section produce strong linear relationships. This provides an attractive avenue to estimate ion temperatures at a given SV using only intrinsic properties. Moreover, experimentally determined Teff correlate with theoretically predicted Teff using with a self-consistent method based on two-temperature theory. The various instrumental and external parameters that influence Teff are additionally discussed.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
08:13Differential Scanning Calorimetry — A Method for Assessing the Thermal Stability and Conformation of Protein Antigen
Published on: March 4, 2017
Related Concept Videos
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Phase Transitions: Melting and Freezing
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...