A Data-Driven Approach to Quantifying Immune States in Sepsis
Published on: February 7, 2025
Sepsis surveillance: an examination of parameter sensitivity and alert reliability
Robert C Amland1, Mark Burghart1, J Marc Overhage1
1Population Health, Cerner Corporation, Kansas City, Missouri, USA.
Objective:
To examine performance of a sepsis surveillance system in a simulated environment where modifications to parameters and settings for identification of at-risk patients can be explored in-depth.
Materials And Methods:
This was a multiple center observational cohort study. The study population comprised 14 917 adults hospitalized in 2016. An expert-driven rules algorithm was applied against 15.1 million data points to simulate a system with binary notification of sepsis events. Three system scenarios were examined: a scenario as derived from the second version of the Consensus Definitions for Sepsis and Septic Shock (SEP-2), the same scenario but without systolic blood pressure (SBP) decrease criteria (near SEP-2), and a conservative scenario with limited parameters. Patients identified by scenarios as being at-risk for sepsis were assessed for suspected infection. Multivariate binary logistic regression models estimated mortality risk among patients with suspected infection.
Results:
First, the SEP-2-based scenario had a hyperactive, unreliable parameter SBP decrease >40 mm Hg from baseline. Second, the near SEP-2 scenario demonstrated adequate reliability and sensitivity. Third, the conservative scenario had modestly higher reliability, but sensitivity degraded quickly. Parameters differed in predicting mortality risk and represented a substitution effect between scenarios.
Discussion:
Configuration of parameters and alert criteria have implications for patient identification and predicted outcomes.
Conclusion:
Performance of scenarios was associated with scenario design. A single hyperactive, unreliable parameter may negatively influence adoption of the system. A trade-off between modest improvements in alert reliability corresponded to a steep decline in condition sensitivity in scenarios explored.
More Related Videos
05:28Evaluation of a Reliable Biomarker in a Cecal Ligation and Puncture-Induced Mouse Model of Sepsis
Published on: December 9, 2022
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Urine Studies II: Urine Culture and Sensitivity Test
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Principles of Disease Surveillance
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...