Related Experiment Video
Updated: Dec 30, 2025

Fast and Sensitive Colloidal Coomassie G-250 Staining for Proteins in Polyacrylamide Gels
Published on: August 3, 2009
Laterally Aggregated Polyacrylamide Gels for Immunoprobed Isoelectric Focusing
Shaheen Jeeawoody1,2, Kevin A Yamauchi1,2, Alison Su1,2
1Department of Bioengineering , University of California Berkeley , Berkeley , California 94720 , United States.
Abstract:
Immunoprobed isoelectric focusing (IEF) resolves proteins based on differences in isoelectric point (pI) and then identifies protein targets through immunoprobing of IEF-separated proteins that have been immobilized onto a gel scaffold. During the IEF stage, the gel functions as an anti-convective medium and not as a molecular sieving matrix. During the immunoprobing stage, the gel acts as an immobilization scaffold for IEF-focused proteins via photoactive moieties. Here, we characterized the effect of gel pore size on IEF separation and in-gel immunoassay performance. We modulated polyacrylamide (PA) gel pore size via lateral chain aggregation initiated by PEG monomers. During IEF, the 2% PEG highly porous PA gel formulation offered higher resolution (minimum pI difference ∼0.07 ± 0.02) than unmodified 6%T, 3.3%C (benchmark) and 6%T, 8%C (negative control) PA gels. The highly porous gels supported a pH gradient with slope and linearity comparable to benchmark gels. The partition coefficient for antibodies into the highly porous gels (K = 0.35 ± 0.02) was greater than the benchmark (3×) and negative control (1.75×) gels. The highly porous gels also had lower immunoassay background signal than the benchmark (2×) and negative control (3×) gels. Taken together, lateral aggregation creates PA gels that are suitable for both IEF and subsequent in-gel immunoprobing by mitigating immunoprobe exclusion from the gels while facilitating removal of unbound immunoprobe.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...