Related Experiment Video
Updated: Dec 29, 2025

Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
Short-term outcome after ventral hernia repair using self-gripping mesh in sublay technique - A retrospective cohort
Felix Harpain1, Kerstin Wimmer1, Christopher Dawoud1
1Department of Surgery, Division of General Surgery, Medical University Vienna, Austria.
Background:
Hernia repair in sublay technique is widely accepted for ventral hernias, as it appears to be advantageous in terms of complication and recurrence rates. Self-gripping meshes are increasingly used for hernia repair with retromuscular mesh positioning. However, real-life data on the safe use in that specific indication are still lacking. The purpose of this study is the evaluation of short-term postoperative outcome of self-gripping versus conventional non-self-gripping meshes in sublay hernia repair.
Materials And Methods:
This retrospective analysis assessed patients undergoing ventral hernia repair in sublay technique between January 2011 and July 2018 at the Department of Surgery, Medical University of Vienna. 244 consecutive patients were eligible for final analysis. Patients were grouped according to the utilized mesh. Baseline characteristics and peri-as well as postoperative outcome was assessed.
Results:
There was no significant difference in baseline characteristics between the two groups. Median follow-up was 11 months (IQR 3-30). The overall complication rate (28.3% versus 13.7%, p = 0.005) due to an increased rate of seromas (17.3% versus 6.8%, p = 0.013) and surgical site infections (12.6% versus 4.3%, p = 0.021) was significantly higher in patients with a self-gripping mesh. Significantly more patients with a self-gripping mesh needed a surgical intervention (21.3% versus 9.4%, p = 0.011).
Conclusion:
In sublay ventral hernia repair, the use of self-gripping meshes is associated with a higher overall complication rate and an increased rate of complication-associated surgical interventions when compared to non-self-gripping mesh placements.