Dental, skeletal and soft tissue effects of the Distal Jet appliance: A prospective clinical study
Rachelle Simões Reis1, José F C Henriques1, Guilherme Janson1
1Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Ortodontia (Bauru/SP, Brazil).
Objective:
This study evaluated the dental, skeletal and soft tissue effects in Class II malocclusion patients treated with Distal Jet appliance, compared to an untreated control group.
Methods:
44 patients with Class II malocclusion were divided into two groups: Group 1 (experimental) - 22 patients, mean age of 12.7 years, treated with the Distal Jet appliance for a mean period of 1.2 years; Group 2 (control) - 22 untreated patients, mean age of 12.2 years, followed by a mean period of 1.2 years. Lateral cephalograms were obtained before treatment (T0) and at the end of the distalization (T1).Independent t test was used to identify intergroup differences.
Results:
When compared to control group, the Distal Jet produced a significant increase in mandibular plane angle (0.7 ± 2.0o). The maxillary second molars presented distal inclination (6.6 ± 3.8o), distalization (1.1 ± 1.1 mm) and extrusion (1.3 ± 2.1 mm). The maxillary first molars distalized by 1.2 ± 1.4 mm. The maxillary first premolars mesialized by 3.4 ± 1.1 mm. The maxillary incisors showed slight labial tipping of 4.3 ± 4.7o and were protruded by 2.4 ± 1.7 mm. There were no significant changes in the facial profile. The overjet increased 1.5 ± 1.1 mm and overbite had no significant changes.
Conclusion:
The Distal Jet appliance is effective to distalize the maxillary first molars, but promotes increase in mandibular plane angle, distal inclination, extrusion and distalization of maxillary second molars, mesialization of maxillary first premolars, proclination and protrusion of maxillary incisors, and increase in overjet, when compared to a control group.