Related Experiment Video
Updated: Dec 29, 2025

Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
Introducing "Insertive Stripping Voltammetry": Electrochemical Determination of Sodium Ions Using an Iron(III)
Alex L Suherman1, Mengjiang Lin1, Bertold Rasche1
1Department of Chemistry, Physical and Theoretical Chemistry Laboratory , Oxford University , South Parks Road , Oxford OX1 3QZ , U.K.
Abstract:
A new type of stripping voltammetry is introduced, in which the preconcentration step includes ion insertion into a solid phase followed by a quantification step in which the ion is expelled via linear sweep voltammetry. Specifically, sodium-ion concentrations in both aqueous solution and synthetic sweat are electrochemically determined using iron(III) phosphate-modified glassy carbon electrodes. The electrochemical method consists of a potentiostatic step, holding the potential of -0.5 V vs saturated calomel electrode (SCE) for 100 s, followed by linear sweep voltammetry. It is shown that a thermal and mechanical pretreatment at 800 °C and with a ball mill, respectively, improve the electrochemical response of the iron(III) phosphate toward Na+. The involved structural and morphological changes were assessed by thermogravimetric analysis, scanning electron microscopy, and powder X-ray diffraction. The sensor exhibits a good selectivity toward Li+ and K+ and shows a linear response between 0.025 and 0.2 M Na+. As a proof-of-principle, the sensor was used to determine the sodium level in synthetic sweat.
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...