Bruch membrane opening-minimum rim width (BMO-MRW) assessment effectively distinguishes mild glaucoma patients from healthy individuals. This new optical coherence tomography (OCT) method shows strong diagnostic capability, similar to standard peripapillary retinal nerve fibre layer (pRNFL) analysis.
Area of Science:
- Ophthalmology
- Medical Imaging
- Glaucoma Diagnosis
Background:
- Bruch membrane opening-minimum rim width (BMO-MRW) is a novel diagnostic metric for glaucoma using Spectralis optical coherence tomography (OCT).
- Current glaucoma diagnosis relies on peripapillary retinal nerve fibre layer (pRNFL) assessment.
Purpose of the Study:
- To evaluate the diagnostic utility of BMO-MRW and pRNFL measurements from Spectralis OCT in differentiating healthy eyes from mild primary open-angle glaucoma (POAG).
- To compare the diagnostic performance of BMO-MRW with standard pRNFL analysis.
- To investigate if a linear discriminant function (LDF) combining BMO-MRW and pRNFL parameters improves diagnostic accuracy.
Main Methods:
- A prospective, cross-sectional study included 136 eyes (68 mild POAG, 68 healthy controls) matched by propensity score.
- MRW and pRNFL thickness were measured using the BMO-MRW protocol and standard glaucoma application on Spectralis OCT.
- Receiver operating characteristic (ROC) curves were analyzed to determine the area under the curve (AUC) for diagnostic accuracy.
Main Results:
- Both BMO-MRW parameters and pRNFL thickness were significantly reduced in the POAG group (p < 0.001).
- The BMO-MRW parameters demonstrated good diagnostic accuracy, with AUCs up to 0.879 for global RNFL thickness (standard application) and 0.875 for the LDF.
- No statistically significant difference was found between the AUCs of the tested methods.
Conclusions:
- BMO-MRW parameters exhibit significant capability in differentiating mild glaucoma from healthy eyes.
- The developed LDF using the BMO-MRW OCT protocol did not outperform isolated BMO-MRW or pRNFL parameters in diagnostic accuracy.