Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
Lacrimal drainage function after cheese wiring of lacrimal passage intubation
Shizuka Koh1,2, Shintaro Ochi3, Yasushi Inoue3
1Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Room E7, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan. skoh@ophthal.med.osaka-u.ac.jp.
Purpose:
To investigate how cheese wiring affects lacrimal drainage function by quantitative assessment of tear function and punctal dimensions.
Methods:
Patients who underwent lacrimal passage intubation between January 2017 and September 2018 were enrolled prospectively. Among these patients, those with postoperative cheese wiring who received lacrimal passage intubation in one eye met the criteria for further investigation. The subjective symptoms of epiphora, dimensions of puncta, lower tear meniscus, and tear clearance were assessed postoperatively in both the involved eye and untreated contralateral eye. Punctum dimensions were analysed using the digital slit-lamp image. Tear meniscus and tear clearance were assessed by anterior segment optical coherence tomography.
Results:
Postoperative cheese wiring was observed in 68 of 314 eyes. Among these cases, 36 patients (age 70.5 ± 11.7 years) had cheese wiring only in one eye: with the involvement of both puncta in 15 patients (group A) and only the lower punctum in 21 patients (group B). There was no patient with the involvement of only the upper punctum. While tear function of the involved eyes in group B did not differ from that of the untreated eye, it was significantly decreased in group A compared with that in untreated control eyes (p < 0.05). The tear clearance rate correlated significantly with the upper punctum dimensions (p < 0.05), but not with the lower punctum.
Conclusion:
Analysis of cheese wiring after lacrimal passage intubation with tear function demonstrated that the integrity of the puncta and the canaliculus is important for lacrimal drainage.
Related Concept Videos
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy Suctioning II: Procedure
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...