Use of a pH-sensitive polymer in a microextraction and preconcentration method directly combined with
Raúl González-Martín1, Idaira Pacheco-Fernández2, Binoy Maiti3
1Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), Tenerife, 38206, Spain.
Abstract:
A pH-sensitive polymer based on the poly(styrene-alt-maleic anhydride) co-polymer serves as basis to develop a microextraction method (pH-HGME) in direct combination with high-performance liquid chromatography (HPLC) and fluorescence detection (FD) for the determination of seven organic compounds, including three polycyclic aromatic hydrocarbons (PAHs), three monohydroxylated PAHs and one alkylphenol, in urine. The method bases on the structural modification of the pH-sensitive polymer in the aqueous sample at a high pH value, followed by the formation and insolubilization of a hydrogel containing the preconcentrated analytes by decreasing the pH, and the direct injection of the hydrogel-rich phase in the HPLC-FD system. The optimization of the main variables permitted the selection of low amounts of aqueous sample (10 mL), which was mixed with 10 mg of co-polymer also present in a low volume (150 µL) of concentrated NaOH. The method further requires the addition of 200 µL of concentrated HCl, 3 min of stirring, and 15 min of centrifugation. This pH-HGME-HPLC-FD method presented low limits of detection, ranging from 0.001 µg L-1 to 0.09 µg L-1 in ultrapure water, average relative recoveries of 96.9% for the concentration level of 0.60 µg L-1, and enrichment factors between 1.50 and 17.7. The proposed method also exhibited high precision, with intermediate relative standard deviations lower than 16% for a concentration level of 0.60 µg L-1. The developed pH-HGME-HPLC-FD method performed adequately when analyzing two human urine samples provided by a non-smoker male and a smoker female, respectively. One of the target analytes (2-hydroxynaphthalene) was quantified in both samples using the standard addition method, with a predicted concentration of 7.3 ± 0.4 µg L-1 in the non-smoker male urine and 19.3 ± 0.6 µg L-1 in the smoker female urine.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors