Related Experiment Video
Updated: Dec 29, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
A Prospective Trial to Compare Deep Inspiratory Breath Hold With Prone Breast Irradiation
Naamit K Gerber1, Sherry X Yan1, Benjamin A Levinson2
1Department of Radiation Oncology, New York University Langone Perlmutter Cancer Center, New York, New York.
Purpose:
To compare heart and lung doses for adjuvant whole breast irradiation (WBI) between radiation plans generated supine with deep inspiratory breath hold (S-DIBH) and prone with free-breathing (P-FB) and examine the effect of breast volume (BV) on dosimetric parameters.
Methods And Materials:
Patients with left breast ductal carcinoma in situ or invasive cancer receiving adjuvant WBI were enrolled on a single-institutional prospective protocol. Patients were simulated S-DIBH and P-FB; plans were generated using both scans. Wilcoxon signed-rank and rank-sum tests were used to compare intrapatient differences between plans for the entire cohort and within BV groups defined by tertiles.
Results:
Forty patients were enrolled. Thirty-four patients are included in the analysis owing to patient withdrawal or inability to hold breath. With WBI dose of 4005 to 4256 cGy, mean heart dose (MHD) was 80 cGy in S-DIBH and 77 cGy in P-FB (P = .08). Mean ipsilateral lung dose (MLD) was 453 cGy in S-DIBH and 45 cGy in P-FB (P < .0001). Mean and max left anterior descending artery doses were 251 cGy and 551 cGy in S-DIBH, respectively (P = .1), and 324 cGy and 993 cGy in P-FB, respectively (P = .3). Hot spot and separation were 109% and 22 cm in S-DIBH, respectively, and 107% and 16 cm in P-FB, respectively (P < .0001). For patients with smallest BV, S-DIBH improved MHD and left anterior descending artery doses; for those with largest BV, P-FB improved cardiac dosimetry. With increasing BV, there was an increasing advantage of P-FB for MHD (P = .05), and max (P = .03) and mean (P = .02) left anterior descending artery doses, and the reduction in MLD, hot spot, and separation with P-FB increased (P < .05).
Conclusions:
MHD did not differ between P-FB and S-DIBH, whereas MLD was significantly lower with P-FB. Analysis according to breast volume revealed improved cardiac dosimetry with S-DIBH for women with smallest BV and improved cardiac dosimetry with P-FB for women with larger BV, thereby providing a dosimetric rationale for using breast size to help determine the optimal positioning for WBI.
More Related Videos
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
03:07Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...