Related Experiment Video
Updated: Dec 28, 2025

05:42
Dynamic Navigation for Dental Implant Placement
Published on: September 13, 2022
4.3K
[Precise implant insertion technology for measuring dental implant placement].
Lu-Ming Jia1, Jin-Xiu He1, Jia-Yi Lu1
1State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthetics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.
Summary
This study introduces a novel, measurable technique for precise dental implant placement. The dynamic control measuring ruler system enhances accuracy and simplifies site evaluation, improving outcomes for all implant systems.
Area of Science:
- Dental Implantology
- Surgical Navigation
- Medical Device Technology
Background:
- Accurate dental implant placement is crucial for restoration success.
- Current digital surgical guides and navigation systems have limitations including high costs, multiple procedures, and accuracy issues.
- Physicians often rely on free-hand techniques due to the impracticality of existing digital methods.
Purpose of the Study:
- To present a precise, measurable implantation insertion technology applicable to all dental implant systems.
- To address the lack of time-saving and practical methods for implant site evaluation in preoperative, intraoperative, and postoperative phases.
- To improve the accuracy and efficiency of dental implant procedures.
Main Methods:
- A dynamic control measuring ruler system, including measuring and intraoperative locating rulers, was developed.
- 3D spatial measurement of the operative area was performed preoperatively.
- Implant planning and quantitative guidance were based on measured data and cone beam CT scans.
- The entire implantation process was guided by the dynamic control measuring ruler with verification.
Main Results:
- The presented method enables quantification of preoperative space analysis.
- It provides precise intraoperative guidance for implant insertion.
- Postoperative site measurement and evaluation are facilitated, allowing for positional adjustments.
- Improved implantation accuracy was achieved.
Conclusions:
- This measurable technique offers a practical solution for precise dental implant placement.
- The dynamic control measuring ruler system enhances accuracy, simplifies evaluation, and is suitable for widespread adoption in dental implantation.
- The technology addresses limitations of current digital methods, offering a more accessible and accurate approach.
Keywords:
analytical rulersimplantation siteintraoperative locating rulersoral implant surgeryprecise implant insertionreal-time measurable
