Thorpe tube and oxygen flow restrictor: what's flow accuracy?
Frédéric Duprez1,2,3, Adrien Dubois4, Sandra Ollieuz5
1Service des Soins Intensifs, Hôpital Epicura, Site Hornu, Boussu, Belgium. frederic.duprez@condorcet.be.
Abstract:
Oxygen gas flowmeters (OGF) are used to regulate the oxygen flow in acute and chronic care. In hospitals, Thorpe tubes (TT) are the classical systems most used for delivering oxygen. In recent years, the oxygen flow restrictor (OFR) has appeared. These devices use a series of calibrated openings in a disk that can be adjusted to deliver different flow rates. These devices have a reputation for delivering more accurate oxygen flow rates compared to classical OGFs. However, to our knowledge, few study has examined this supposition. This study aimed to compare and evaluate the accuracy and precision of the ready-to-use TTs and OFRs. OGFs were selected from hospitals in Belgium and France. Before performing the flow measurements, the inlet pressure was checked. The accuracy of the OGF was analyzed with a calibrated thermal mass flowmeter (RED Y COMPACT™ GCM-0 to 20 L/min-VÖGTLIN Instruments). Different flows (2, 4, 6, 9 or 12 L/min) were evaluated. Linear regression analysis, bias (with confidence interval) and lower and upper limit of the agreement were calculated for TTs and OFRs. All measurements are expressed in absolute values. Four-hundred-seventy-six TTs and 96 OFRs were analyzed. The intra-class correlation coefficient calculated for the calibrated thermal mass flowmeter was > 0.99 and reflected the excellent reliability of our measurements. For TTs, the bias value was - 0.24 L/min (± 0.88), and the limits of agreement were - 1.97 to 1.48 L/min. For OFRs, the bias value was - 0.30 L/min (± 0.54), and the limits of agreement were - 1.36 to 0.77 L/min. As the flow increased, the accuracy of all analyzed OGFs decreased. With the increasing flow, some data fell outside the limits of agreement, and the trend increased with the elevated oxygen flow. TTs were less accurate compared to OFRs due to the increased flow variability. However, for TTs and OFRs, as the required flow is elevated, the dispersion of values increases on both sides of the actual flow.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Poiseuille's Law and Reynolds Number
Pipe Flowrate Measurement: Problem Solving