Related Experiment Video
Updated: Dec 28, 2025

Longitudinal In Vivo Imaging of the Cerebrovasculature: Relevance to CNS Diseases
Published on: December 6, 2016
Cantu syndrome: A longitudinal review of vascular findings in three individuals
Ashley Parrott1, Rachel Lombardo2, Nicole Brown1
1Division of Human Genetics, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Abstract:
Cantu syndrome is a rare autosomal dominant disorder caused by missense variants in ABCC9 and KCNJ8. It is characterized by hypertrichosis, neonatal macrosomia, coarse facial features, and skeletal anomalies. Reported cardiovascular anomalies include cardiomegaly, structural defects, collateral vessels, and rare report of arteriovenous malformation (AVM). Arterial dilation is reported in a few individuals including one with surgical intervention for a thoracic aortic aneurysm. The natural history of this aortopathy including the rate of progression or risk for dissection is unknown and longitudinal patient data is unavailable. We present data from vascular imaging in three individuals with genetically confirmed Cantu syndrome over 3 to 14 years of follow-up. All patients had generally stable aortic dilation, which did not reach the surgical threshold, including one individual followed closely through pregnancy. In adulthood, one individual had a maximum ascending aortic measurement of 4.2 cm. Two pediatric patients had aortic root or ascending z-scores of approximately +3. A large asymptomatic pelvic AVM was identified in one individual on head-pelvis MRI. While the data reported in these individuals is reassuring regarding the risk for progressive disease, further data from additional individuals with Cantu syndrome is needed to best inform screening recommendations, improve understanding of dissection risk, and guide management.
More Related Videos
08:05Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Overview of the Vascular System
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation