Differences in dry-bulb temperature do not influence moderate-duration exercise performance in warm environments when vapor pressure is equivalent
Related Experiment Video
Updated: Dec 28, 2025

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Tze-Huan Lei1,2, Zachary J Schlader3, Ahmad Munir Che Muhamed4
1School of Sport, Exercise and Nutrition, Massey University, Palmerston North, New Zealand.
Purpose:
Recent studies have determined that ambient humidity plays a more important role in aerobic performance than dry-bulb temperature does in warm environments; however, no studies have kept humidity constant and independently manipulated temperature. Therefore, the purpose of this study was to determine the contribution of dry-bulb temperature, when vapor pressure was matched, on the thermoregulatory, perceptual and performance responses to a 30-min cycling work trial.
Methods:
Fourteen trained male cyclists (age: 32 ± 12 year; height: 178 ± 6 cm; mass: 76 ± 9 kg; [Formula: see text]: 59 ± 9 mL kg-1 min-1; body surface area: 1.93 ± 0.12 m2; peak power output: 393 ± 53 W) volunteered, and underwent 1 exercise bout in moderate heat (MOD: 34.9 ± 0.2 °C, 50.1 ± 1.1% relative humidity) and 1 in mild heat (MILD: 29.2 ± 0.2 °C, 69.4 ± 0.9% relative humidity) matched for vapor pressure (2.8 ± 0.1 kPa), with trials counterbalanced.
Results:
Despite a higher weighted mean skin temperature during MOD (36.3 ± 0.5 vs. 34.5 ± 0.6 °C, p < 0.01), none of rectal temperature (38.0 ± 0.3 vs. 37.9 ± 0.4 °C, p = 0.30), local sweat rate (1.0 ± 0.3 vs. 0.9 ± 0.4 mg cm-2 min-1, p = 0.28), cutaneous blood flow (283 ± 116 vs. 287 ± 105 PU, p = 0.90), mean power output (206 ± 37 vs. 205 ± 41 W, p = 0.87) or total work completed (371 ± 64 vs. 369 ± 70 kJ, p = 0.77) showed any difference between environments during the work trial. However, all perceptual measures (perceived exertion, thermal discomfort, thermal sensation, skin wettedness, pleasantness, all p < 0.05) were affected detrimentally during MOD compared to MILD.
Conclusion:
In a warm and compensable environment, dry-bulb temperature did not influence high-intensity cycling performance when vapor pressure was maintained, whilst the perceptual responses were affected.
Related Concept Videos
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Vapor Pressure
Vaporization
Clausius-Clapeyron Equation
Body Temperature
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...