Related Experiment Videos
Evaluation of effects of ozone exposure on influenza infection in mice using several indicators of susceptibility
M K Selgrade1, J W Illing, D M Starnes
1Inhalation Toxicology Division, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711.
Abstract:
Mice were exposed to 1 ppm O3, 3 hr/day, for 5 consecutive days. Separate groups of mice were infected with influenza following each of the individual exposures. A twofold increase in the incidence of mortality and a 3-day decrease in mean survival time were observed in mice infected after the second exposure. There were no effects on percentage mortality or mean survival time due to exposure to 1 ppm O3 in mice infected after the first, third, fourth, or fifth exposure. When the exposure concentration was lowered to 0.5 ppm, there were no effects on mortality in mice infected after the second exposure. Five, daily, 3-hr exposures to 1 ppm O3 had no effect on virus titers in the lungs of mice infected after either the second or fifth exposure. In contrast, wet lung weights were significantly enhanced over infected air controls in mice infected after the second O3 exposure at both 1 and 0.5 ppm but not at 0.25 ppm exposure concentrations. This effect on lung wet weight was observed in mice infected with a dose of virus which produced 7-33% mortality in controls as well as in mice infected with a sublethal dose of virus. Histopathologic changes due to sublethal influenza infection, including nonsuppurative pneumonitis and necrosis, squamous metaplasia and hyperplasia of the epithelium lining the bronchi and bronchioles, were more severe in mice infected after the second of five, 1 ppm O3 exposure than in comparable air controls. Sublethal infection caused a loss of lung volume with secondary reduction in diffusing capability and homogenity of ventilation distribution. These latter two effects were also exacerbated in mice infected after the second of five, 1 ppm O3 exposures as compared to air controls. When mice were infected after the fifth, 1 ppm O3 exposure, there was no effect due to ozone on either lung wet weight or histopathology. The data indicate that O3 has little if any effect on antiviral defense mechanisms since virus titers in the lungs were not affected by O3 exposure. However, mortality and morbidity, as indicated by lung wet weights, histopathology, and pulmonary function changes, were enhanced by O3 exposure in mice infected after the second of five exposures suggesting that symptoms due to infection can be enhanced in the absence of enhanced virus replication, possibly due to synergistic effects of O3 and virus in production of lung pathology.(ABSTRACT TRUNCATED AT 400 WORDS)
Insights
Ozone exposure before influenza infection increased mortality and lung damage in mice, particularly after the second exposure. This occurred without affecting virus levels, suggesting ozone exacerbates illness through other mechanisms.
Area of Science:
- Environmental Health
- Toxicology
- Respiratory Medicine
Background:
- Ozone (O3) is a major air pollutant.
- Influenza virus causes significant respiratory illness.
- The combined effects of ozone and influenza infection are not fully understood.
Purpose of the Study:
- To investigate the impact of ozone exposure on influenza virus infection in mice.
- To determine if ozone affects viral replication or host response.
- To assess ozone's role in modulating influenza-induced lung pathology and mortality.
Main Methods:
- Mice were exposed to varying concentrations of ozone (0.25-1 ppm) for 3 hours daily for 5 days.
- Influenza virus infection was administered after specific ozone exposures.
- Mortality, survival time, lung wet weight, viral titers, histopathology, and pulmonary function were assessed.
Main Results:
- Ozone exposure at 1 ppm after the second exposure significantly increased mortality and decreased survival time.
- Lung wet weights and histopathological damage were exacerbated after the second ozone exposure at 1 and 0.5 ppm.
- Ozone exposure did not affect lung virus titers, indicating no impairment of antiviral defenses.
- Effects were most pronounced after the second exposure and diminished by the fifth exposure.
Conclusions:
- Ozone exposure can worsen influenza symptoms and outcomes, independent of viral load.
- The second ozone exposure appears critical for enhancing susceptibility to influenza.
- Synergistic effects between ozone and influenza contribute to increased lung pathology and mortality.