Analysis of local setup errors of sub-regions in cone-beam CT-guided post-mastectomy radiation therapy
Jidan Zhou1, Shuai Li1, Chengwei Ye1
1Department of Radiotherapy, Division of Radiation Physics, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, P.R. China.
Abstract:
The purpose of the study was to quantify local setup errors and evaluate the planning target volume (PTV) margins for sub-regions in cone-beam computed tomography (CBCT)-guided post-mastectomy radiation therapy (PMRT). The local setup errors of 20 patients undergoing CBCT-guided PMRT were analysed retrospectively. Image registration between CBCT and planning CT was performed using four sub-regions of interest (ROIs): the supraclavicular area (SROI), ipsilateral chest wall region (CROI), ipsilateral chest wall plus supraclavicular region (SROI + CROI) and vertebral region (TROI). Bland-Altman analysis, correlation, local setup errors and PTV margins among these ROIs were evaluated. There was no significant consistency or correlation for registration results between the TROI and the CROI or SROI regions on any translational axis. When using the SROI + CROI as the ROI, the systematic error (Σ) and random error (σ) of the local setup errors for the CROI region were 1.81, 1.19 and 1.76 mm and 1.84, 2.64 and 3.00 mm along the medial-lateral (ML), superior-inferior (SI) and anterior-posterior (AP) directions, respectively. The PTV margins for the CROI region were 5.80, 4.82 and 6.50 mm. The Σ and σ of the local setup errors for the SROI region were 1.29, 1.15 and 0.77 mm and 1.96, 2.65 and 2.2 mm, respectively, and the PTV margins were 4.59, 4.73 and 3.47 mm. Large setup errors and local setup errors occur in PMRT. The vertebral body should not be a position surrogate for the supraclavicular region or chest wall. To compensate for the local setup errors, different PTV margins are required, even with CBCT guidance.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
07:47Author Spotlight: 3D Scanning and Augmented Reality for Enhanced Cancer Surgery Communication
Published on: December 15, 2023