Sensitivity improvement of YAP(Ce) cameras for imaging of secondary electron bremsstrahlung x-rays emitted during
Seiichi Yamamoto1, Mitsutaka Yamaguchi2, Takashi Akagi3
1Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya 461-8673, Japan.
Abstract:
Low-energy x-ray imaging of secondary electron bremsstrahlung x-rays emitted during carbon-ion irradiation is a promising method for range estimation and could be used for imaging with almost clinical dose levels of carbon ion. However, the number of counts in images with clinical dose levels is relatively small, making it difficult to obtain precise range estimations. Since improving the sensitivity of the x-ray camera may solve this issue, we developed two new types of x-ray cameras. One uses a 1 mm thick, 40 mm × 40 mm cerium-doped yttrium aluminum perovskite (YA1O3: YAP(Ce)) scintillator plate combined with a 2 inch square flat panel photomultiplier tube (FP-PMT) contained in a 2 cm thick tungsten shield with a pinhole collimator positioned 50 mm from the scintillator; the other uses a 0.5 mm thick, 20 mm × 20 mm YAP(Ce) scintillator plate combined with a 1 inch square position sensitive photomultiplier tube (PSPMT) contained in the same tungsten shield with a pinhole collimator, but with the scintillator positioned closer (30 mm) to the pinhole collimator to obtain a similar field of view. For both cameras, we used a wider angle (∼55°) pinhole collimator to measure the phantom closer to improve sensitivity. Although the 40 mm × 40 mm YAP(Ce) camera had high system spatial resolution, the background count fractions were high and produced a high count area at the center of the images due to the pulse pileup of the signals. With the 20 mm × 20 mm YAP(Ce) camera, we obtained x-ray images with low background counts without a high count area at the image center. By smoothing the measured images, we were able to estimate the ranges even for clinical dose levels. We therefore confirmed that one of our newly developed YAP(Ce) cameras had high sensitivity and is promising for the imaging of secondary electron bremsstrahlung x-rays during irradiation of carbon ions in clinical conditions.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017