Semi-continuous Monitoring of Cr(VI) and Cr(III) during a Soil Extraction Process by Means of an Ion Transfer Device

Willy Cahya Nugraha1,2, Haruka Nagai1, Shin-Ichi Ohira3,4

  • 1Department of Chemistry, Kumamoto University, 2-39-1 Kurokami, Kumamoto, 860-8555, Japan.

Related Concept Videos

Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
4.4K
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
723
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
934
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
554
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
495
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
1.4K