ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
Published on: August 19, 2021
Sample-Specific Prediction Error Measures in Spectroscopy
Carl Emil Eskildsen1,2, Tormod Næs1
1Nofima AS, Norwegian Institute for Food, Fisheries and Aquaculture Research, Ås, Norway.
Abstract:
In applied spectroscopy, the purpose of multivariate calibration is almost exclusively to relate analyte concentrations and spectroscopic measurements. The multivariate calibration model provides estimates of analyte concentrations based on the spectroscopic measurements. Predictive performance is often evaluated based on a mean squared error. While this average measure can be used in model selection, it is not satisfactory for evaluating the uncertainty of individual predictions. For a calibration, the uncertainties are sample specific. This is especially true for multivariate calibration, where interfering compounds may be present. Consider in-line spectroscopic measurements during a chemical reaction, production, etc. Here, reference values are not necessarily available. Hence, one should know the uncertainty of a given prediction in order to use that prediction for telling the state of the chemical reaction, adjusting the process, etc. In this paper, we discuss the influence of variance and bias on sample-specific prediction errors in multivariate calibration. We compare theoretical formulae with results obtained on experimental data. The results point towards the fact that bias contribution cannot necessarily be neglected when assessing sample-specific prediction ability in practice.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Related Concept Videos
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
NMR Spectrometers: Resolution and Error Correction
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Uncertainty in Measurement: Accuracy and Precision
UV–Vis Spectrometers