Related Experiment Video
Updated: Dec 27, 2025

Optical Scatter Microscopy Based on Two-Dimensional Gabor Filters
Published on: June 2, 2010
Three-dimensional curvelet-based dictionary learning for speckle noise removal of optical coherence tomography
Mahad Esmaeili1,2, Alireza Mehri Dehnavi1, Fedra Hajizadeh3
1Department of Bioelectrics and Biomedical Engineering, Medical Image & Signal Processing Research Center, School of Advanced Technologies in Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Abstract:
Optical coherence tomography (OCT) is a recently emerging non-invasive diagnostic tool useful in several medical applications such as ophthalmology, cardiology, gastroenterology and dermatology. One of the major problems with OCT pertains to its low contrast due to the presence of multiplicative speckle noise, which limits the signal-to-noise ratio (SNR) and obscures low-intensity and small features. In this paper, we recommend a new method using the 3D curvelet based K-times singular value decomposition (K-SVD) algorithm for speckle noise reduction and contrast enhancement of the intra-retinal layers of 3D Spectral-Domain OCT (3D-SDOCT) images. In order to benefit from the near-optimum properties of curvelet transform (such as good directional selectivity) on top of dictionary learning, we propose a new plan in dictionary learning by using the curvelet atoms as the initial dictionary. For this reason, the curvelet transform of the noisy image is taken and then the noisy coefficients matrix in each scale, rotation and spatial coordinates is passed through the K-SVD denoising algorithm with predefined 3D initial dictionary that is adaptively selected from thresholded coefficients in the same subband of the image. During the denoising of curvelet coefficients, we can also modify them for the purpose of contrast enhancement of intra-retinal layers. We demonstrate the ability of our proposed algorithm in the speckle noise reduction of 17 publicly available 3D OCT data sets, each of which contains 100 B-scans of size 512×1000 with and without neovascular age-related macular degeneration (AMD) images acquired using SDOCT, Bioptigen imaging systems. Experimental results show that an improvement from 1.27 to 7.81 in contrast to noise ratio (CNR), and from 38.09 to 1983.07 in equivalent number of looks (ENL) is achieved, which would outperform existing state-of-the-art OCT despeckling methods.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Imaging Studies III: Computed Tomography
Two-Dimensional Microscopy in Microbiology
Three-Dimensional Microscopy in Microbiology

