David M Yen1, Michael T Murray2, Robert Puchalski3
1Specialty Physician Associates, Bethlehem, Pennsylvania, USA.
Objectives:
(1) To evaluate safety, tolerability, and technical success of lidocaine iontophoresis and a tympanostomy tube placement system for adults in an office setting and (2) to meet regulatory evidence requirements for new drugs and devices.
Study Design:
Prospective, multicenter, single arm.
Setting:
Patients were recruited in 8 community-based practices in the United States between June and September 2017.
Subjects And Methods:
This study evaluated tympanic membrane anesthesia and tube placement in 30 adults. Anesthesia was achieved via iontophoresis of a lidocaine/epinephrine solution. Tube placement was conducted using an integrated myringotomy and tube delivery system. Tolerability of tube placement was measured using a patient-reported visual analog scale from 0 mm (no pain) to 100 mm (worst possible pain). Mean pain score was compared to a performance goal of 45 mm, where statistical superiority represents mild pain or less. Technical success and safety through 3 weeks postprocedure were evaluated.
Results:
Twenty-nine (29/30, 96.7%) patients had tube(s) successfully placed in all indicated ears. One patient demonstrated inadequate tympanic membrane anesthesia, and no tube placement was attempted. The mean (SD) pain score of 9.4 (15.7) mm was statistically superior to the performance goal. There were no serious adverse events. Seven nonserious events were related to device, procedure, or drug: inadequate anesthesia (1), vertigo (1), and dizziness (1) at the time of procedure and ear discomfort (1), tube occlusion (2), and medial tube migration (1) postprocedure.
Conclusion:
Lidocaine iontophoresis provides acceptable tympanic membrane anesthesia for safe, tolerable, and successful in-office tube placement using an integrated myringotomy and tube delivery system.
More Related Videos
09:07Author Spotlight: Advancing Endoscopic Ossiculoplasty – Techniques, Innovations, and Practical Guidance for Clinical Integration
Published on: January 26, 2024
09:18A Comparative Study of Drug Delivery Methods Targeted to the Mouse Inner Ear: Bullostomy Versus Transtympanic Injection
Published on: March 8, 2017
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Suctioning II: Procedure
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...