Related Experiment Video
Updated: Dec 26, 2025

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Clinical Impact of an Electronic Dashboard and Alert System for Sedation Minimization and Ventilator Liberation: A
Brian J Anderson1,2, David Do3,4, Corey Chivers5
1Division of Pulmonary, Allergy and Critical Care Medicine, Department of Medicine, University of Pennsylvania, Philadelphia, PA.
Abstract:
Sedation minimization and ventilator liberation protocols improve outcomes but are challenging to implement. We sought to demonstrate proof-of-concept and impact of an electronic application promoting sedation minimization and ventilator liberation.
Design:
Multi-ICU proof-of-concept study and a single ICU before-after study.
Setting:
University hospital ICUs.
Patients:
Adult patients receiving mechanical ventilation.
Interventions:
An automated application consisting of 1) a web-based dashboard with real-time data on spontaneous breathing trial readiness, sedation depth, sedative infusions, and nudges to wean sedation and ventilatory support and 2) text-message alerts once patients met criteria for a spontaneous breathing trial and spontaneous awakening trial. Pre-intervention, sedation minimization, and ventilator liberation were reviewed daily during a multidisciplinary huddle. Post-intervention, the dashboard was used during the multidisciplinary huddle, throughout the day by respiratory therapists, and text alerts were sent to bedside providers.
Measurements And Main Results:
We enrolled 115 subjects in the proof-of-concept study. Spontaneous breathing trial alerts were accurate (98.3%), usually sent while patients were receiving mandatory ventilation (88.5%), and 61.9% of patients received concurrent spontaneous awakening trial alerts. We enrolled 457 subjects in the before-after study, 221 pre-intervention and 236 post-intervention. After implementation, patients were 28% more likely to be extubated (hazard ratio, 1.28; 95% CI, 1.01-1.63; p = 0.042) and 31% more likely to be discharged from the ICU (hazard ratio, 1.31; 95% CI, 1.03-1.67; p = 0.027) at any time point. After implementation, the median duration of mechanical ventilation was 2.20 days (95% CI, 0.09-4.31 d; p = 0.042) shorter and the median ICU length of stay was 2.65 days (95% CI, 0.13-5.16 d; p = 0.040) shorter, compared with the expected durations without the application.
Conclusions:
Implementation of an electronic dashboard and alert system promoting sedation minimization and ventilator liberation was associated with reductions in the duration of mechanical ventilation and ICU length of stay.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...