Measurement of Azimuthal Anisotropy of Muons from Charm and Bottom Hadrons in pp Collisions at sqrt[s]=13  TeV with

G Aad1, B Abbott2, D C Abbott3

  • 1CPPM, Aix-Marseille Université, CNRS/IN2P3, Marseille, France.

Related Concept Videos

Atomic Nuclei: Nuclear Magnetic Moment00:59

Atomic Nuclei: Nuclear Magnetic Moment

All atomic nuclei are positively charged. When they have a nonzero spin, they behave like rotating charges. As a consequence of their charge and spin, these nuclei generate a magnetic field (B). This, in turn, gives rise to a magnetic moment (μ), which is randomly oriented in the absence of an external magnetic field. When an external magnetic field (B0) is applied, the magnetic moment vectors can align with the field or against it in 2 + 1 orientations. A hydrogen nucleus, which is just a...
2.9K
Thomson's e/m Experiment01:19

Thomson's e/m Experiment

In a beam of charged particles created by a heated cathode, the particles move at different speeds. However, many applications need a beam with uniform particle speeds. An arrangement known as a velocity selector uses electric and magnetic fields to pick particles with a particular speed from the beam.
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
6.3K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.3K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.5K
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.1K
Atomic Radii and Effective Nuclear Charge03:08

Atomic Radii and Effective Nuclear Charge

The elements in groups of the periodic table exhibit similar chemical behavior. This similarity occurs because the members of a group have the same number and distribution of electrons in their valence shells.
61.0K