Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Microscope Integrated Intraoperative Optical Coherence Tomography-Guided DMEK in Corneas with Poor Visualization
Namrata Sharma1, Pranita Sahay1, Prafulla K Maharana1
1Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Microscope-integrated intraoperative optical coherence tomography (Mi-OCT) aids Descemet membrane endothelial keratoplasty (DMEK) in challenging cases. This technology improves visualization, leading to successful graft attachment and better visual outcomes in corneas with poor visibility.
Area of Science:
- Ophthalmology
- Corneal Surgery
- Medical Imaging
Background:
- Corneal decompensation with poor visualization presents surgical challenges for endothelial keratoplasty.
- Descemet membrane endothelial keratoplasty (DMEK) requires precise graft placement, which can be difficult in compromised corneas.
Purpose of the Study:
- To evaluate the effectiveness of microscope-integrated intraoperative optical coherence tomography (Mi-OCT) for performing DMEK in eyes with limited visibility.
- To assess the impact of Mi-OCT guidance on graft attachment and visual outcomes in challenging DMEK procedures.
Main Methods:
- A prospective interventional case series involving 25 patients undergoing Mi-OCT-guided DMEK for corneal decompensation with poor visualization.
- Key outcome measures included graft attachment on postoperative day 3 and the need for re-bubbling, with a six-month follow-up.
Main Results:
- Complete graft attachment was achieved in 72% of cases, with 16% requiring re-bubbling due to detachment. All grafts were attached at six months.
- Mi-OCT facilitated visualization of anatomical structures, graft configuration, and potential complications like peripheral folds and retained tags.
- Significant improvements were observed in corrected distance visual acuity and central corneal thickness post-surgery.
Conclusions:
- Mi-OCT is a valuable tool for DMEK surgery in corneas with poor visualization, aiding in the identification of host anatomy and graft dynamics.
- The use of Mi-OCT can lead to successful graft attachment and improved visual function in challenging endothelial keratoplasty cases.