Related Experiment Video
Updated: Dec 26, 2025

Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
Sonographic Assessment of Intravascular Fluid Estimate (SAFE) Score by Using Bedside Ultrasound in the Intensive Care
Keith Killu1,2, Victor Coba1, Dionne Blyden1
1Department of Surgery, Division of Acute Care Surgery, Henry Ford Hospital, Detroit, MI, USA.
Objective:
The objective of the study was to use an ultrasound-based numerical scoring system for assessment of intravascular fluid estimate (SAFE) and test its validity.
Methods:
A prospective, observational study was carried out in the surgical intensive care unit (ICU) of an urban tertiary care teaching hospital. Patient's intravascular volume status was assessed using the standard methods of heart rate, blood pressure, central venous pressure, cardiac output, lactate and saturation of venous oxygen, and others. This was compared with assessment using bedside ultrasound evaluation of the cardiac function, inferior vena cava, lungs, and the internal jugular vein. Applying a numerical scoring system was evaluated by Fisher's exact testing and multinomial logistic model to predict the volume status based on ultrasound scores and the classification accuracy.
Results:
61 patients in the ICU were evaluated. 21 (34.4% of total) patients diagnosed with hypovolemia, and their ultrasound volume score was -4 in 14 (66.7%) patients, -3 in 5 (23.8%) patients, and 0 in 2 (9.5%) patients (p < 0.001). 18 (29.5% of total) patients diagnosed with euvolemia, and their ultrasound volume score was 0 in 11 (61.1%) patients, +1 in 4 (22.2%) patients, and -1 in 1 (5.6%) patient (p < 0.001). 18 (29.5% of total) patients diagnosed with euvolemia, and their ultrasound volume score was 0 in 11 (61.1%) patients, +1 in 4 (22.2%) patients, and -1 in 1 (5.6%) patient (p < 0.001). 18 (29.5% of total) patients diagnosed with euvolemia, and their ultrasound volume score was 0 in 11 (61.1%) patients, +1 in 4 (22.2%) patients, and -1 in 1 (5.6%) patient (p < 0.001). 18 (29.5% of total) patients diagnosed with euvolemia, and their ultrasound volume score was 0 in 11 (61.1%) patients, +1 in 4 (22.2%) patients, and -1 in 1 (5.6%) patient (.
Conclusion:
Using the SAFE scoring system to identify the IVV status in critically ill patients significantly correlates with the standard measures. A SAFE score of -4 to -2 more likely represents hypovolemia, -1 to +1 more likely represents euvolemia, and +2 to +4 more likely to be hypervolemia.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies II: Ultrasonography