Related Experiment Video
Updated: Dec 26, 2025

High-throughput Screening for Broad-spectrum Chemical Inhibitors of RNA Viruses
Published on: May 5, 2014
An in silico and in vitro pipeline for the rapid screening of helicase modulators
Eleni Papakonstantinou1,2, Flora Bacopoulou3, Vasileios Megalooikonomou4
1Laboratory of Genetics, Department of Biotechnology, School of Food, Biotechnology and Development, Agricultural University of Athens, Athens, Greece.
Abstract:
To evaluate the potency of potential helicase modulators, we developed an assay of helicase enzyme activity. Using a DNA or RNA biotin labelled oligonucleotide and after the addition of a recombinant helicase, the nucleic acid unwinds, causing the emission of luminescence, which is quantified with a particular antibody. In our assay, one of the DNA oligos was biotinylated, while the other was labelled with digoxygenin (DIG), both in their 5' termini. The biotin molecule immobilises the DNA duplex on a neutravidin-coated plate and the helicase activity is measured through the unwinding of DNA, due to ATP activation. The subsequent release of DIG-labelled oligos results in a luminescence signal measured with a chemiluminescence antibody. Our goal was to provide a high throughput screening method for potential helicase inhibitors. The method described in this paper has been demonstrated to be fast, easy and reproducible and doesn't use radiochemicals.