Related Experiment Video
Updated: Dec 25, 2025

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
Paths of the cervical instantaneous axis of rotation during active movements-patterns and reliability
William Venegas1, Marta Inglés2, Álvaro Page3
1Facultad de Ingeniería Mecánica, Escuela Politécnica Nacional, c/ Ladrón de Guevara E11-253, 17012759, Quito, Ecuador.
Abstract:
The instantaneous helical axis (IHA) is a characteristic of neck movement that is very sensitive to changes in coordination and that has potential in the assessment of functional alterations. For its application in the clinical setting, normative patterns must be available, and its reliability must be established. The purpose of this work is to describe the continuous paths of the IHA during cyclic movements of flexion-extension (FE), lateral bending (LB), and axial rotation (AR) and to quantify their reliability. Fifteen healthy volunteers participated in the study; two repetitions were made on the same day (by different operators) and over an 8-day interval (by the same operator) to evaluate the inter-operator and inter-session reliability, respectively. The paths described by the IHA suggest a sequential movement of the vertebrae in the FE movement, with a large vertical displacement (mean, 10 cm). The IHA displacement in LB and AR movements are smaller. The paths described by the IHAs have a very high reliability for FE movement, although it is somewhat lower for LB and RA movements. The standard error of measurement (SEM) is less than 0.5 cm. These results show that the paths of the IHA are reliable enough to evaluate changes in the coordination of intervertebral movement. Graphical abstract A video photogrammetry system is used to record the cyclic movements of the neck, from which the continuous trajectories of the associated instantaneous helical axis (IHA) are calculated. We have analyzed the movements of flexion-extension (FE), lateral flexion (LB), and axial rotation (AR) for a sample of 15 healthy subjects. The measurements have been repeated with two different operators (in the same session) and in two separate sessions (same operator). IHA displacement patterns have been obtained in each movement, and the reliability of the measurement of such IHA trajectories has been estimated.
Related Concept Videos
Rotational Motion about a Fixed Axis
Articulations of the Vertebral Column
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Anatomical Movements
Here are some common anatomical movements:
Flexion and extension motions are in the sagittal (anterior–posterior) plane of motion. These movements take place at the shoulder, hip, elbow, knee, wrist,...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Instantaneous Center of Zero Velocity
To analyze this, consider two points on the wheel: point A and point B. The absolute velocity of point B can be expressed as the vector sum of the absolute velocity of point A and the relative velocity of point B with respect to point A. To simplify this analysis,...