Related Experiment Video
Updated: Dec 25, 2025

Optimization of the Longa Middle Cerebral Artery Occlusion Method for Complete Reperfusion
Published on: November 22, 2024
High-resolution compressed-sensing time-of-flight MRA in a case of acute ICA/MCA dissection
Theo Demerath1,2, Leo Bonati3, Amgad El Mekabaty4
1Department of Neuroradiology, University Medical Center Freiburg, Breisacherstrasse 64, 79106, Freiburg, Germany. Theo.demerath@uniklinik-freiburg.de.
Purpose:
Acute, isolated intracranial dissection (ICD) represents a rare and challenging cause of acute stroke. DSA is considered to be the gold standard imaging modality in patients with ICD. The role of novel, high-resolution (HR) compressed-sensing (CS) time-of-flight (TOF) MRA techniques in ICDs is unclear.
Methods:
A 22-year-old male patient with an isolated right ICA/MCA intracranial dissection underwent "conventional" 3-T TOF MRA, HR CS TOF MRA and also DSA including digital rotational angiography.
Results:
Unlike the "conventional" TOF MRA, HR CS TOF MRA provided comparable image quality to rotational angiography and a dissection membrane was clearly visible in both techniques.
Conclusion:
In this single case study, we demonstrated the feasibility of a novel HR CS TOF in a case of an acute isolated intracranial ICA/MCA dissection, which needs to be validated in a larger case series.