Abstract:
One of the challenges preventing rapid, onsite voltammetric detection of arsenic(III) is the overlapping oxidation peak of copper(II). This paper describes a novel methodology for the voltammetric detection of trace levels of arsenic(III) in the presence of high copper(II) concentrations (up to the action level of 1.3 mg L-1 set by the US EPA for drinking water). Square wave stripping voltammetry tests were performed using disposable carbon screen printed electrodes modified with gold nanostars on samples buffered with Britton-Robinson buffer. The optimized parameters for accurate codetection of arsenic(III) and copper(II) were a buffer pH of 9.5, a loading of gold nanostars of 2.39*10-5 nmol per electrode, a deposition voltage of -0.8 V, and a deposition time of 180 s. Based on calibration testing, the limits of detection for arsenic(III) and copper(II) were determined to be 2.9 μg L-1 and 42.5 μg L-1, respectively. Furthermore, the linear ranges for arsenic and copper were 0-100 μg L-1 and 0-250 μg L-1 with sensitivities of 0.101 μA (μg L-1)-1 and 0.121 μA (μg L-1)-1, respectively. Interference testing was performed with several common ionic species, sodium bicarbonate, sodium chloride, tannic acid, iron(iii) chloride, magnesium chloride, calcium nitrate, and sodium sulfate, with only sodium bicarbonate significantly affecting the response. Validation testing in real-world samples was performed by comparison with graphite furnace atomic absorption spectroscopy. The validation testing demonstrated good accuracy and precision, expressed as percent recovery and relative standard deviation (RSD), respectively, in river water and tap water, with mean percent recoveries of 87.7% (RSD = 4.20%) and 83.2% (RSD = 10.02%), respectively.
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Electrodeposition
Electrodeposition can...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...