Related Experiment Video
Updated: Dec 25, 2025

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Rapid-Deployment Aortic Valves for Patients With a Small Aortic Root: A Single-Center Experience
Iuliana Coti1, Thomas Haberl1, Sabine Scherzer1
1Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria.
Aortic valve replacement using small rapid-deployment valves shows good survival and improved heart function, even with prosthesis-patient mismatch. This procedure is safe and effective for patients with small aortic roots.
Area of Science:
- Cardiovascular Surgery
- Biomaterials Science
- Medical Devices
Background:
- Aortic valve replacement in patients with small aortic roots presents challenges regarding prosthesis-patient mismatch.
- The EDWARDS INTUITY valve system is a rapid-deployment aortic valve used in these cases.
Purpose of the Study:
- To evaluate the survival and hemodynamic performance of small rapid-deployment aortic valves (19 and 21 mm).
- To assess the impact of prosthesis-patient mismatch on outcomes in this patient group.
Main Methods:
- A prospective study included 659 patients with severe aortic stenosis receiving rapid-deployment valves.
- 217 patients (32.9%) received small bioprostheses (19 or 21 mm) and were analyzed for outcomes.
Main Results:
- Mean gradients were low (14.8 mmHg at discharge, 13.6 mmHg at 1 year).
- Prosthesis-patient mismatch occurred in 35.5% of patients, but did not significantly affect overall survival.
- Perioperative mortality was 1.8%, with 1-year and 5-year survival rates of 91% and 79%, respectively.
- Significant improvement in New York Heart Association functional class was observed.
Conclusions:
- Surgical aortic valve replacement with rapid-deployment valves demonstrates favorable hemodynamic performance and reduced prosthesis-patient mismatch.
- Excellent early- and midterm survival rates and improved functional class were noted in patients with small aortic annuli.