Related Experiment Video
Updated: Dec 25, 2025

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Early Postoperative Intraocular Pressure is Associated With Better Pressure Control After XEN Implantation
Carlo A Cutolo1,2, Michele Iester1,2, Alessandro Bagnis1,2
1Clinica Oculistica, Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DiNOGMI), University of Genoa.
Abstract:
PRéCIS:: Gel stent implantation is a bleb-forming surgery designed to achieve predictable pressure drop. An early low intraocular pressure (IOP) is associated with the long-term success of the procedure.
Purpose:
To identify the variables associated with the success of the XEN procedure.
Patients And Methods:
This was part of a prospective, uncontrolled, consecutive case series study. Patients with primary open-angle glaucoma or pseudo-exfoliative glaucoma were included. All the patients underwent surgical XEN implant procedure with mitomycin-C subconjunctival injection 20 minutes before surgery. Success criteria were an off-medication IOP of 6 to 16 mm Hg 12 months after surgery; no additional glaucoma surgery; no visual threatening complications, no visual acuity loss >1 Snellen line. One eye per patient was considered for statistical analysis. A univariate Cox proportional hazard regression analysis was performed to identify potential risk factors for surgical failure. Then, a multivariate Cox model was built.
Results:
One hundred twenty-three patients were recruited in this study: 93 patients underwent XEN implantation alone whereas 30 the combined procedure with phacoemulsification and intraocular lens implantation. Univariate Cox regression showed that the day after surgery intraocular lens>9 mm Hg was associated with surgical failure (P=0.02) and a postoperative number of needlings ≥2 in the follow-up was also predictive of surgical failure (P<0.01). These data were confirmed by a multivariate model too. At 1 year the surgical success criteria were 76% in the group with 24-hour IOP≤9 mm Hg, whereas it was 43% when above 9 mm Hg (P=0.026).
Conclusions:
Our study shows that an early IOP≤9 mm Hg is predictive of the efficacy of the procedure during 1-year follow-up, whereas more than 2 needlings are predictive of failure.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment