Related Experiment Video
Updated: Dec 25, 2025

Generation of Human Nasal Epithelial Cell Spheroids for Individualized Cystic Fibrosis Transmembrane Conductance Regulator Study
Published on: April 11, 2018
Importance of Nebulizer Drying for Patients With Cystic Fibrosis
John E Moore1,2,3,4,5, Rachel E Moore6,7,8,9,10, Jane Bell6,7,8,9,10
1Northern Ireland Public Health Laboratory, Department of Bacteriology, Belfast City Hospital, Belfast, Northern Ireland, United Kingdom. jemoore@niphl.dnet.co.uk.
Background:
Nebulizer therapy is an important treatment component for patients with cystic fibrosis (CF). Nebulizer manufacturers' guidelines advocate thorough nebulizer drying after washing. The aim of this study, therefore, was to examine the microbiology associated with nebulizer drying, particularly related to Pseudomonas control, and to examine microbiologically non-adherence to the recommended drying procedures.
Methods:
Four aspects of nebulizer drying were examined in 3 common nebulizers, including examination of the drying profile, improvement to the drying profile of assembled nebulizers, survival of Pseudomonas aeruginosa in tap water and in tap water plus 0.5% (v/v) dishwashing detergent, and the effect of drying of P. aeruginosa in tap water and tap water plus residual sputum (1%v/v, 10%v/v). Microbiologic examination was performed by using P. aeruginosa (5 clinical CF strains plus 1 National Collection of Type Cultures Reference strain).
Results:
There were differences in the time to complete dryness between disassembled and fully assembled nebulizers. Vigorous repeated shaking was unable to drive off all residual water on assembled nebulizers. P. aeruginosa counts did not decrease significantly in either tap water or in tap water plus detergent after 24 h storage at ambient temperature. In contrast, all Pseudomonas organisms were killed when nebulizers were dried for 24 h, even when contaminated with 1% and 10% sputum. Dishwashing detergent did not demonstrate any antibacterial activity.
Conclusions:
This study demonstrated that nebulizer drying, if applied properly, had the ability to reduce counts of P. aeruginosa to non-detectable levels. Equally, this study showed that, if the device was not dried thoroughly and moisture remained, then the device was able to support the survival of P. aeruginosa at high numbers, which constituted an infection risk to the patient with CF. This information may help educate and inform the patient with CF about the importance of proper nebulizer drying for Pseudomonas control to improve patient awareness and safety.
More Related Videos
06:57The WinCF Model - An Inexpensive and Tractable Microcosm of a Mucus Plugged Bronchiole to Study the Microbiology of Lung Infections
Published on: May 8, 2017
07:38Design and Development of a Model to Study the Effect of Supplemental Oxygen on the Cystic Fibrosis Airway Microbiome
Published on: August 3, 2021
Related Concept Videos
Cystic Fibrosis: Management
Sinus disease and chronic...
Inhaled Medications
Cystic Fibrosis: Pathogenesis
CF is primarily caused by a genetic mutation in a chromosome 7 gene coding for the cystic fibrosis transmembrane conductance regulator (CFTR) protein. The most common gene mutation leading to CF is the ΔF508 mutation,...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Suctioning the Nasopharyngeal Airway
Equipment Required