Related Experiment Video
Updated: Dec 25, 2025

Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
End-of-Therapy Echocardiography May Not Be Needed in All in Patients With Endocarditis
Abinash Virk1, Kirsten M Schutte2, James M Steckelberg1
1Division of Infectious Diseases, Department of Medicine, Mayo Clinic, Rochester, Minnesota, USA.
Background:
The American Heart Association (AHA) guidelines for infective endocarditis (IE) management recommend end-of-therapy (EOT) echocardiography (ETE) to "establish a new baseline" and based on "expert opinion."
Methods:
Medical records of IE patients treated between January 2005 and December 2011 were reviewed. Utilization of ETE and cumulative incidence of re-treatment with antimicrobials or cardiovascular surgery (re-Rx/CVS) within 1 year after EOT were evaluated.
Results:
A total of 243 patients completed clinical follow-up at EOT and 170 at 1 year after EOT. One hundred seventy-seven of 243 (72.8%) underwent ETE, the majority (51.4%) transthoracic echocardiography. One hundred thirty-three of 177 (75.1%) were without new/worsened signs or symptoms (new/w-SSx). One hundred forty-one of 177 (79.7%) overall and 117/133 (87.9%) patients without new/w-SSx had no new ETE findings as compared with initial echocardiography. Among 36/177 (20.3%) with new ETE findings, 20/36 (55.6%) had new/w-SSx; ETE findings were more likely in patients with new/w-SSx (39.2% vs 8.3%; P < 0.001) at EOT. Patients were at increased risk of re-Rx/CVS with either new ETE findings (hazard ratio [HR], 25.86; 95% confidence interval [CI], 7.64-87.56; P < .001) or new/w-SSx (HR, 5.35; 95% CI, 2.87-9.95; P < .001). The highest risk of re-Rx/CVS was in patients with both new/w-SSx and new ETE findings (HR, 45.94; 95% CI, 19.07-110.71). Conversely, only 7/187 (3.4%) patients without new/w-SSx who had an ETE required re-Rx/CVS.
Conclusions:
The majority of patients without new/w-SSx at EOT will not have new ETE findings or need re-Rx/CVS within 1 year after EOT. EOT new/w-SSx is associated with new ETE findings and predicts the need for re-Rx/CVS. Further study is needed to determine whether patients without new/w-SSx need ETE.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Endocarditis III: Medical Management
Endocarditis IV: Nursing Management
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Endocarditis I: Introduction
Endocarditis II: Clinical Features of Infective Endocarditis