Related Experiment Video
Updated: Dec 25, 2025

Advanced Self-Healing Asphalt Reinforced by Graphene Structures: An Atomistic Insight
Published on: May 31, 2022
Cyclic-Dependent Damage Evolution in Self-Healing Woven SiC/[Si-B-C] Ceramic-Matrix Composites at Elevated
Longbiao Li1, Pascal Reynaud2, Gilbert Fantozzi2
1College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, No.29, Yudao St., Nanjing 210016, China.
Abstract:
Cycle-dependent damage evolution in self-healing, 2.5D woven Hi-NicalonTM SiC/[Si-B-C] and 2D woven Hi-NicalonTM SiC/[SiC-B4C] ceramic-matrix composites (CMCs) at 600 and 1200 °C was investigated. The cycle-dependent damage parameters of internal friction, dissipated energy, Kachanov's damage parameter, and broken fiber fraction were obtained to describe damage development in self-healing CMCs. The relationships between cycle-dependent damage parameters and multiple fatigue damage mechanisms were established. The experimental fatigue damage development of self-healing Hi-NicalonTM SiC/[Si-B-C] and Hi-NicalonTM SiC/[SiC-B4C] composites was predicted for different temperatures, peak stresses, and loading frequencies. The cycle-dependent damage evolution of self-healing Hi-NicalonTM SiC/[Si-B-C] and Hi-NicalonTM SiC/[SiC-B4C] composites depends on temperature, testing environment, peak stress, and loading frequency. For the Hi-NicalonTM SiC/[Si-B-C] composite, temperature is a governing parameter for the fatigue process. At an elevated temperature of 600 °C in an air atmosphere, the internal frictional parameter of Hi-NicalonTM SiC/[Si-B-C] composite decreases first and then increases with applied cycle number; however, at an elevated temperature of 1200 °C in an air atmosphere, the internal frictional parameter of Hi-NicalonTM SiC/[Si-B-C] composite decreases with applied cycle number, and the interface shear stress at 1200 °C is much lower than that at 600 °C. For Hi-NicalonTM SiC/[SiC-B4C] composite at 1200 °C, loading frequency is a governing parameter for the fatigue process. The degradation rate of interface shear stress is much higher at the loading frequency of 0.1 Hz than that at the loading frequency of 1 Hz.
More Related Videos
10:52Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot Heater System
Published on: August 7, 2018
07:13High Temperature Fabrication of Nanostructured Yttria-Stabilized-Zirconia YSZ Scaffolds by In Situ Carbon Templating Xerogels
Published on: April 16, 2017
Related Concept Videos
Fatigue
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...