Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and
Qi Wan, Qiang Lei1, Peng Wang1
1Department of Radiology, the First Affiliated Hospital of Guangzhou Medical University.
Objective:
The aim of the study was to compare intravoxel incoherent motion diffusion-weighted imaging (DWI) for evaluating lung cancer using single-shot turbo spin-echo (TSE) and single-shot echo-planar imaging (EPI) in a 3T MR system.
Methods:
Both single-shot TSE-DWI and single-shot EPI-DWI were scanned twice respectively for 15 patients with lung cancer. Distortion ratio, signal-to-noise ratio, and contrast-to-noise ratio were compared between the 2 techniques. The Bland-Altman analysis was performed to analyze reproducibility between the parameters of TSE-DWI and EPI-DWI. Short-term test-retest repeatability, as well as interobserver agreement, was evaluated using the coefficient of variation (CV) and the intraclass correlation coefficient (ICC).
Result:
Turbo spin-echo DWI has lower signal-to-noise ratio and similar contrast-to-noise ratio compared with EPI-DWI. Distortion ratio of TSE-DWI was significantly smaller than that of EPI-DWI. The apparent diffusion coefficient (ADC) and true diffusivity (D) of TSE-DWI showed higher values than those of EPI-DWI. The Bland-Altman analysis showed unacceptable limits of agreement between these 2 sequences. Test-retest repeatability was good for ADC and D of EPI-DWI (CV, 14.11%-16.60% and 17.08%-19.53%) and excellent for ADC and D of TSE-DWI (CV, 4.8%-6.19% and 6.05%-8.71%), but relatively poor for perfusion fraction (f) and pseudo-diffusion coefficient (D*) (CV, 25.95%-27.70% and 56.92%-71.84% for EPI, 23.67%-28.67% and 60.85%-70.17% for TSE). For interobserver agreement, both techniques were good to excellent in ADC and D (The lower limit of 95% confidence interval for ICC was almost all greater than 0.75), whereas D* and f had higher interobserver variabilities with D* of TSE-DWI showing poorest reproducibility (ICC, -0.27 to 0.12).
Conclusions:
Lung DWI or IVIM using TSE could provide distortion-free images and improve the test-retest robustness of ADC and D as compared with EPI-DWI; however, it might exert a negative effect on perfusion parameter D*.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...