Related Experiment Video
Updated: Dec 25, 2025

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Preventing Dental Surgical Fires: Characterizing Nasal-Cannulated Supplemental Oxygen Pooling in an In Situ Dental
Bradley W Cox1, James E Jones2, Mark A Saxen3
1From the James Whitcomb Riley Hospital for Children, Indiana University School of Dentistry.
Objectives:
Surgical operatory fires continue to occur in the United States, often with devastating consequences. Because more than 21% concentrations of oxygen are necessary for the onset of such combustion, this study examined fluctuations of surgical site oxygen levels. Better understanding how these more than 21% concentrations occur will not only add to surgical fire prevention efforts generally but also potentially reduce patient or staff harm and practitioner liability as well.
Methods:
Performing an in situ dental procedure with supplemental nasal-cannulated oxygen and a dental dam, we measured oxygen pooling, defined as any fraction of inspired oxygen (FIO2) greater than the 21% FIO2 of air, on top of and behind a dental dam, and during the application of high-volume intraoral suction.
Results:
Findings indicated statistically significantly higher concentrations (as much as twice the <30% recommended safe level) behind the dental dam compared with on top of it. During real-time measurements of FIO2 for four 120-second trials per participant, oxygen levels exhibited significant fluctuation above and below a more stringent 24.9% safety threshold established in prior research. Application of high-speed intraoral dental suction reduced FIO2 to near atmospheric levels in 30 (96.7%) of 31 of the cases by 60 seconds.
Conclusions:
These results demonstrate the elevated risk associated with above-safe levels of oxygen pooling during a simple dental procedure. Although future research is needed to still more exactly characterize conditions leading to the onset of surgical fires, this study also demonstrates the ability of high-speed intraoral suction to dramatically and rapidly decrease that risk.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management