Related Experiment Video
Updated: Dec 25, 2025

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Design of an amplitude-splitting hard x-ray delay line with subnanoradian stability
Abstract:
We present the design and analysis of a hard x-ray split-delay optical arrangement that combines diffractive and crystal optics. Transmission gratings are employed to achieve the much-desired amplitude splitting and recombination of the beam. Asymmetric channel-cut crystals are utilized to tune the relative delay time. The use of a dispersion-compensation arrangement of the crystals allows the system to achieve subnanoradian pointing stability during a delay scan. It also minimizes wavefront distortion and preserves the pulse front and pulse duration. We analyze the performance of a prototype design that can cover a delay time range of 15 ps with a sub-20 fs time resolution at 10 keV. We anticipate that this system can fully satisfy the very demanding stability requirements for performing split-pulse x-ray photon correlation spectroscopy measurements for the investigation of fast atomic scale dynamics in complex disordered matter.
More Related Videos
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
09:13Implementation of a Nonlinear Microscope Based on Stimulated Raman Scattering
Published on: July 6, 2019