The influence of the α/β ratio on treatment time iso-effect relationships in the central nervous system
Bleddyn Jones1,2, Thomas Klinge3,4,5, John W Hopewell2
1Gray Laboratory, Department of Oncology, University of Oxford, Oxford, UK.
Abstract:
Purpose: To investigate the influence of changes in α/β ratio (range 1.5-3 Gy) on iso-effective doses, with varying treatment time, in spinal cord and central nervous system tissues with comparable radio-sensitivity. It is important to establish if an α/β ratio of 2 Gy, the accepted norm for neuro-oncology iso-effect estimations, can be used.Methods: The rat spinal cord irradiation data of Pop et al. provided ED50 values for radiation myelopathy for treatment times that varied from minutes to ∼6 days. Analysis using biphasic repair kinetics, allowing for variable dose-rates, provided the best fit with repair half-times of 0.19 and 2.16 hr, each providing ∼50% of overall repair; with an α/β ratio 2.47 Gy (CI 1.5-3.95 Gy). Using the above data set, graphical methods were used to investigate changes in the repair parameters for differing fixed α/β ratios between 1.5 and 3.0 Gy. Two different intermittent dose delivery equations were used to evaluate the implications in a radiosurgery setting.Results: Changes in the α/β ratio (1.5-3.0 Gy) have a minor effect on equivalent doses for radiation myelopathy for treatment durations of a few hours. Changing the α/β value from 2 Gy to 2.47 Gy, modified equivalent single doses by < 1% when overall treatment times ranged from 0.1 to 5.0 hr. Significant changes were only found for treatment times longer than 5-10 hr. These two α/β ratios were also compared in a practical radiosurgery situation, using two different models for estimating BED, again there was no significant loss of accuracy.Conclusions: It is reasonable to use an α/β ratio of 2 Gy for CNS tissue, with the same repair half-times as published in the original publication by Pop et al., in situations where the assessment of the BED in radiosurgery is used with other form of radiotherapy. In radiosurgery, the variation in BED with treatment duration (for a fixed physical dose) is very similar, but absolute BED values depend on the α/β value. In radiosurgery, clinical recommendations obtained using BED calculations using the originally proposed α/β ratio of 2.47 Gy are still appropriate. For calculations involving a combination of radiosurgery and other modalities, such as fractionated radiotherapy, it would be appropriate in all cases to apply a value of 2 Gy, the accepted norm in neuro-oncology, without significant loss of accuracy in the radio-surgical component. This may have important applications in retreatment situations.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
11:01Quantitative Autoradiographic Method for Determination of Regional Rates of Cerebral Protein Synthesis In Vivo
Published on: June 28, 2019
Related Concept Videos
Compartment Models: Two-Compartment Model
Time Course of Drug Effect
Nonlinear Pharmacokinetics: Dependence of Elimination Half-Life and Dose Clearance
A study on guinea pigs examined the...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Factors Affecting Drug Response: Overview