A rapid, accurate image simulation strategy for mega-voltage cone-beam computed tomography
Mengying Shi1,2, Marios Myronakis2, Matthew Jacobson2
1Medical Physics Program, Department of Physics and Applied Physics, University of Massachusetts Lowell, Lowell, MA, United States of America.
Abstract:
Intensive computation time is required to simulate images of electronic portal imaging device (EPID) using Monte Carlo (MC) technique, limiting the development of applications associated with EPID, such as mega-voltage cone-beam computed tomography (MV-CBCT). In this study, a fast, accurate simulation strategy for MV-CBCT utilizing the FastEPID technique has been developed and validated. During FastEPID simulation, photon detection was determined by pre-calculated photon energy deposition efficiency (η) and particle transport within the EPID was replaced with a pre-calculated optical photon spread function. This method is capable of reducing the time required for EPID image simulation by a factor of 90-140, without compromising image quality. MV-CBCT images reconstructed from the FastEPID simulated projections have been validated against measurement in terms of mean Hounsfield unit (HU), noise, and cupping artifact. These images were obtained with both a Catphan 604 phantom and an anthropomorphic pelvis phantom, under treatment beam energies of 2.5 MV, 6 MV, and 6 MV flattening filter free. The agreement between measurement and simulation was excellent in all cases. This novel strategy was capable of reducing the run time of a full scan simulation of MV-CBCT performed on a CPU cluster to a matter of hours, rather than weeks or months required by a conventional approach. Multiple applications associated with MV-CBCT (e.g. imager design optimization) are anticipated to gain from the implementation of this novel simulation strategy.
More Related Videos
08:46Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
Published on: April 13, 2016
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography